Areas we serve › New York City › Commercial building inspection
A commercial building inspection NYC buyers order is one document in a deal that also needs filings, records and a lender’s paperwork, and the rules that apply turn mostly on two figures the Department of Finance already holds for each lot: how many floors it has and how many square feet of building. New York City has 109,262 tax lots with commercial floor area. Only 8,933 of them rise above six floors, the point where the city’s facade program begins. Only 18,440 hold more than 25,000 square feet of building, close to the point where Local Law 97 begins. The other 83% sit below that size, and for them the rules that apply are the annual boiler filing, the gas piping cycle, the certificate of occupancy and the sidewalk out front. This page sorts out which rule applies to which building.
Inspecwise is a New York State-licensed, InterNACHI-certified home inspection business based in South Ozone Park, Queens. The license is a home inspector license: it covers residential buildings of one to four dwelling units, and a store, an office or a warehouse falls outside it. What we offer on a commercial building is a visual, non-invasive condition walk-through of what is readily visible, a written report, and a pointer to the filings and records that apply and to who is allowed to sign each one. It is not engineering or architecture, and it does not replace any filing the city requires. We work in English, Urdu, Punjabi and Hindi.
The page runs from the stock to the rules: the commercial lots borough by borough, what our license covers, what a walk-through is next to a property condition assessment and an environmental report, who may sign each city filing, the size thresholds that put a building inside or outside each law, the inspections an owner inherits, the paper trail, and what lenders ask. For local detail, each borough has its own page: Manhattan, Brooklyn, Queens, the Bronx and Staten Island.
The commercial stock of the five boroughs, side by side
A “commercial lot” here is a tax lot with any commercial floor area recorded in the city’s PLUTO file (version 26v2). It counts lots, not buildings and not businesses, and a lot holding an apartment house with one shop at street level is in the count. Manhattan’s 21,983 lots, 20% of the city’s, carry 45% of its commercial floor area. Brooklyn has the most commercial lots, 41,551, and Staten Island is the low-rise end: 4,617 of its 5,590 commercial lots (83%) have one or two floors recorded, against 45% in Brooklyn and 9% in Manhattan.
| Borough | Commercial tax lots | Commercial floor area (million sq ft) | Lots with more than 25,000 sq ft of building | Lots with more than six floors | Lots with one or two floors | Built before 1940 (share of lots with a recorded year) |
|---|---|---|---|---|---|---|
| Manhattan | 21,983 | 814.7 | 7,646 (34.8%) | 5,981 | 1,944 | 78.6% |
| Brooklyn | 41,551 | 405.7 | 4,247 (10.2%) | 1,361 | 18,709 | 75.2% |
| Queens | 28,208 | 345.7 | 3,333 (11.8%) | 861 | 18,904 | 55.7% |
| The Bronx | 11,930 | 197.4 | 2,783 (23.3%) | 703 | 7,054 | 60.2% |
| Staten Island | 5,590 | 64.6 | 431 (7.7%) | 27 | 4,617 | 37.4% |
| New York City | 109,262 | 1,828.1 | 18,440 (16.9%) | 8,933 | 51,228 | 67.2% |
The Bronx stands out in the other direction: 23.3% of its commercial lots hold more than 25,000 square feet of building, against 10.2% in Brooklyn and 11.8% in Queens. Citywide, 67% of commercial lots with a recorded year were built before 1940, and the share runs from 37% on Staten Island to 79% in Manhattan. The city’s year-built field for old buildings is often a rounded estimate, so we quote that share and never a median year. The next table sorts the same lots by building class.
| Borough | Mixed residential-commercial | Retail | Office | Warehouse | Factory | Garage | Apartment buildings with commercial space | All other classes |
|---|---|---|---|---|---|---|---|---|
| Manhattan | 12.1% | 10.7% | 11.2% | 0.8% | 0.1% | 1.3% | 39.6% | 24.3% |
| Brooklyn | 43.5% | 14.1% | 4.3% | 5.8% | 3.5% | 4.3% | 7.8% | 16.6% |
| Queens | 32.2% | 22.1% | 5.7% | 7.6% | 4.4% | 6.2% | 6.3% | 15.4% |
| The Bronx | 15% | 21.3% | 5% | 6.5% | 3.5% | 8.5% | 19.8% | 20.5% |
| Staten Island | 22.3% | 28.8% | 12.5% | 8.4% | 1.3% | 7.5% | 1.2% | 17.9% |
| New York City | 30.1% | 17% | 6.5% | 5.5% | 3% | 4.8% | 14.8% | 18.3% |
The table gives each class family as a share of that borough’s commercial lots. The class is the Department of Finance’s tax label, and it tells you what the city believes the building mostly is (DOF building classes). The mixed residential-commercial family runs from S0, a one-family house with two stores or offices, to S5, a five- or six-family building with one store. Citywide, 32,866 commercial lots (30%) sit in it: 44% of Brooklyn’s commercial lots, 32% of Queens’, 15% of the Bronx’s and 12% of Manhattan’s. A buyer of such a building buys a store and apartments together, so the apartment rules, such as HPD’s annual registration of multiple dwellings with three or more units and the lead-paint rules for buildings built before 1960, come with the store rules. In Manhattan and the Bronx, about 40% and 20% of the commercial lots are apartment buildings with some commercial space, which is why a “commercial” count there includes buildings people think of as residential.
What a home inspector’s license covers, and why a store is outside it
Real Property Law Article 12-B defines a home inspection as the process in which a home inspector observes and reports on the systems and components of a residential building (Real Property Law §444-b). It defines a residential building as a structure of one to four dwelling units and their garages and carports. A store, an office, a warehouse or an apartment building of five or more units is outside that definition. The same article says nothing in it authorizes a home inspector to practice engineering or architecture (§444-g), the mandatory wording of every home-inspection agreement tells the client that home inspectors are not permitted to provide engineering or architectural services (19 NYCRR 197-4.2), and a home inspector may not advertise under the heading of engineers or architects (197-4.9).
The line matters because of what comes later in this page. New York reserves several of the city’s building filings for a professional engineer, a registered architect or a licensed master plumber, and the Education Law lets only licensed people practice engineering or use the title (Education Law §7202) or practice architecture (§7302). A report from a home inspector cannot stand in for any of those signatures, and we do not offer it as one. The license number belongs on every report and in all advertising, so ours is in the footer of every page; here is how to check any inspector’s license with the Department of State.
A building that combines a store with one to four apartments is common in this city and raises a scoping question, because the apartments are residential and the store is not. Ask us how a visit would be divided, and ask the Department of State’s Division of Licensing Services how the home inspector license applies to a building like that, before you rely on either answer. For a house with no store, see our guide to two- and three-family house inspections.
Commercial building inspection NYC: a visual walk-through next to a property condition assessment
A visual condition walk-through records what can be seen on the day without opening walls, moving materials or probing: it notes what looks deteriorated, missing or unsafe, and it says what could not be seen. The standard people usually mean by a property condition assessment is ASTM E2018, and it is built differently. ASTM calls it a voluntary guide, “a reasonable baseline process … on a voluntary basis,” and lists E2018-24, updated 4 January 2024, as the active edition (ASTM E2018-24). It frames the assessment as a walk-through survey of the primary improvements plus research, and it says the goal is to identify and communicate material physical deficiencies to the user and that the assessment is not technically exhaustive.
| Part of the E2018 process | What the guide says | What it means in a deal |
|---|---|---|
| Walk-through survey | Done by a “field observer”; covers exteriors, site work, parking, roofing, structure, plumbing, HVAC, electrical, conveyance and life-safety systems and representative interiors | The visit is the part most people picture, and it is one part of the process |
| Research | Document review and interviews sit beside the walk-through | Ask who requests the records and who talks to the property manager |
| Easily visible limit | The walk-through covers conditions seen without intrusion, relocation or removal of materials or exploratory probing | A report describes the surface and says what was hidden |
| Cost opinions | Defines “immediate costs” as costs for material unsafe conditions, material building or fire code violations, or deficiencies likely to cause a critical failure within a year | Ask whether the report contains a cost section and what it covers |
| Reviewer and qualifications | A “PCR reviewer” (a reviewer of the property condition report) reviews it. The guide recommends, and does not require, a reviewer with an architecture or engineering designation or construction experience, and an exhibit stating both people’s qualifications | Ask who reviewed the report and what the qualifications statement says |
| Outside the scope | Testing, measuring or calculating to judge adequacy, capacity or compliance with any standard; any finding of compliance with fire, building, life-safety, environmental, health or zoning rules | No assessment is a code or zoning clearance |
| Not practice of a licensed profession | The guide says doing the walk-through or reviewing the report is not, by itself, practicing architecture or engineering | It does not make an engineer’s seal unnecessary where a city filing requires one |
The details in the table come from the 2015 edition (E2018-15), whose full text we read; for the 2024 edition ASTM’s free preview shows only the scope and the table of contents, so some clauses may have changed. Inspecwise describes its commercial work as aligned with the ASTM E2018 baseline process. Read that as a description of approach and not as a claim of conformance. A report is only as complete as its parts, so ask any provider, us included, which of the parts above the report you are ordering contains and which it leaves out, and have the answer written into the agreement.
A walk-through also stops short of five things, and a good agreement says so:
- Legal use. The certificate of occupancy fixes it, and only the Department of Buildings issues the certificate. We report what is visible and send you to the record.
- Code determinations. The home inspector Code of Ethics bars an inspector from determining compliance with regulations, codes, laws or ordinances (19 NYCRR 197-4.4), and E2018 itself is not a finding of compliance.
- ADA certification. Both the landlord who owns a building housing a public accommodation and the tenant who operates it are covered by Title III, and in its 2010 rulemaking the Justice Department declined to give local officials authority to certify individual facilities (ADA Title III regulations). No report we write is an ADA certification.
- Environmental findings. Contamination is the subject of a separate report, covered next.
- Engineering conclusions and city filings. The signature belongs to the licensed person named in the matrix further down.
Phase I, transaction screen and condition assessment: three reports, three questions
A condition assessment asks what is wrong with the building. Two other ASTM practices ask a different question, about the land and its history, and a commercial lender or buyer may need one of them as well. They are not substitutes for each other.
| Report | The question it answers | Who must prepare it | What it cannot do |
|---|---|---|---|
| Property condition assessment (ASTM E2018) | What is physically wrong with the improvements, and what will need money | A field observer and a report reviewer, with qualifications set out in the report | Test, measure or find compliance with a code |
| Phase I environmental site assessment (ASTM E1527-21) | Are there recognized environmental conditions: releases or likely releases of hazardous substances or petroleum products | An “environmental professional.” Federal rules let a current Professional Engineer or Professional Geologist license plus three years’ relevant experience qualify (40 CFR 312.10) | Assess building condition |
| Transaction screen (ASTM E1528-22) | A lighter, limited look at environmental risk, less than a Phase I | The free preview does not say; the SBA requires an environmental professional with a reliance letter | Identify recognized environmental conditions, or earn the buyer CERCLA liability protection |
The federal “all appropriate inquiries” rule is aimed at commercial and government buyers, and at any individual buying for non-residential use, who want protection from CERCLA liability after the purchase (EPA’s all-appropriate-inquiries page). Loans under the Small Business Administration’s 7(a) and 504 programs add their own tiers. Its Standard Operating Procedure 50 10, in version 8.1 from 1 October 2026, requires an environmental investigation of all commercial property pledged as collateral. For a loan above $250,000 the minimum start is an Environmental Questionnaire and a Records Search with Risk Assessment; a property whose current or known prior use matches a listed industry code needs a Phase I whatever the loan size; a property with a dry cleaner that uses or used chlorinated or petroleum-based solvents needs a Phase I and then a Phase II; and transaction screens and Phase I and II reports must come from an environmental professional with a reliance letter (SBA SOP 50 10). A condition walk-through is none of these, and we do not write environmental reports.
Who may perform and sign each New York City filing
The matrix below is the part of this page we would keep on the wall beside any commercial building inspection NYC owners commission. It lists the filings that commonly sit around a commercial building, which buildings they reach, who is allowed to do and sign the work, and how often. None of them is ours to perform or certify. When we walk a building, we note what is visible and tell you which of these filings the building appears to need and where to check whether the last one looks current in the public record.
| Filing or inspection | Buildings it reaches | Who may do it and sign it | Cycle or date | Source |
|---|---|---|---|---|
| Facade inspection (Local Law 11 of 1998) | Buildings with any exterior wall greater than six stories, whatever the certificate of occupancy says | A Qualified Exterior Wall Inspector: a New York State licensed Professional Engineer or registered architect in good standing, approved by DOB | Five years on DOB’s pages; Local Law 49 of 2025 sets 6 to 12 years from 1 October 2026 | DOB · Local Law 49 |
| Gas piping (Local Law 152 of 2016) | All buildings except one- and two-family homes and other Occupancy Group R-3 buildings | A Licensed Master Plumber, or a registered journeyman plumber under a master’s direct and continuing supervision | At least every four years, by community district | DOB · Local Law 142 |
| Boiler inspection | Commercial and mixed-use buildings with H- or E-stamped boilers, whatever their capacity | A Licensed Master Plumber or a Licensed Oil Burner Installer | Every year | DOB boiler page · compliance page |
| Elevator inspection and tests | Buildings with elevators | Approved agencies, hired by the owner, for the category tests | Inspected and tested twice a year | DOB |
| Parking-structure assessment | Parking structures, except garages for fewer than three cars, unenclosed unattached lots and garages serving one- and two-family homes | A New York State licensed Professional Engineer who is also a DOB Qualified Parking Structure Inspector | By 1 January 2028, then every four years under Local Law 71 of 2024 | DOB · Local Law 71 |
| Local Law 97 emissions report | Buildings over 25,000 gross square feet, or two or more buildings on one tax lot together over 50,000 | A registered design professional (Professional Engineer or registered architect) must certify the report | Limits from 2024; stricter limits from 2030 | DOB |
| Asbestos survey before permitted work | Pre-1987 buildings; buildings built after 1 April 1987 are exempt from DEP’s certification requirements | A DEP-certified asbestos investigator signs and seals the ACP-5 assessment report | Before DOB issues the permit | DEP |
| Phase I environmental site assessment | A commercial purchase where the buyer wants CERCLA liability protection, or a lender asks | An environmental professional | Before the purchase | ASTM · EPA |
| Cooling-tower registration | Every cooling tower, fluid cooler and evaporative condenser | The owner or property manager registers through the NYC Cooling Tower Registration Portal | On registration | NYC Health |
| Retaining walls | Walls on the owner’s property | The owner must keep them safe; DOB advises a Professional Engineer or registered architect for suspect walls | Continuing | DOB |
Two points before the next table. A registered design professional and a Qualified Exterior Wall Inspector are titles the state and the city confer, and a home inspector holds neither. And two rows in the matrix, the facade interval and the parking-structure cycle, are moving; a later section gives the dates.
Size thresholds: which law a building is in or out of
Whether a law reaches a building usually depends on height, size or use. The table gives each threshold as the city’s own pages state it. Read “in” and “out” as the law’s words and not as our opinion of any one building: a lot may hold several buildings, the Department of Finance’s square footage drives some tests, and the Department of Buildings keeps the lists that decide.
| Law | A building is in when | A building is out when | Source |
|---|---|---|---|
| Facade program | Any exterior wall, or part of one, is greater than six stories | The building is six stories or fewer | 1 RCNY 103-04 |
| Local Law 97 | It exceeds 25,000 gross square feet, or two or more buildings on one tax lot together exceed 50,000 | It is smaller than that | DOB |
| Local Law 87 energy audits | It is over 50,000 gross square feet (or a lot of several buildings is over 100,000) | It is smaller, such as a 12,000 sq ft store building | DOB |
| Local Law 26 of 2004 sprinklers | An office building, or an Occupancy Group E building, is over 100 feet in height; full sprinklers were due by 1 July 2019 | The law speaks only of buildings over 100 feet | DOB |
| Gas piping (Local Law 152) | Any building other than one- and two-family homes and R-3 buildings | DOB’s list of exempt DOF classes: S0, S1, S2, M3 with two or fewer dwelling units, M4 with 20 or fewer occupants, N2 and V. S3, S4 and S5 are not on that list | DOB · DOF classes |
| Boiler inspection | A commercial or mixed-use building (commercial space plus one to five residential units); a residential building of six or more families | A boiler in a residential building of five families or fewer | DOB |
| Parking-structure assessment | A parking structure not on the exclusion list | A garage for fewer than three cars; an unenclosed, unattached lot; a garage serving one- and two-family homes | DOB |
| HPD registration | A multiple dwelling of three or more residential units, each year | A one- or two-family house where the owner or the owner’s immediate family lives | HPD |
| Local Law 1 of 2004 (lead paint) | Multiple dwellings of three or more units built before 1960, and tenant-occupied units in one- and two-unit dwellings built before 1960 | Store space, because the rule is written for residential units | HPD |
The gas-piping row leaves open a question that matters for mixed-use buildings. DOB exempts the classes of a one- or two-family house with one or two stores or offices (S0, S1, S2). It does not name the classes for three- to six-family buildings with one store (S3, S4, S5). Whether they fall inside the law is a reading of two lists and not a sentence DOB prints, so ask a Licensed Master Plumber or DOB before you assume either answer.
| Borough | Commercial lots over 25,000 sq ft | Between 5,000 and 25,000 sq ft | Under 5,000 sq ft | Commercial lots over six floors | All lots over six floors, any use |
|---|---|---|---|---|---|
| Manhattan | 7,646 | 11,036 | 3,301 | 5,981 | 7,685 |
| Brooklyn | 4,247 | 12,975 | 24,329 | 1,361 | 2,112 |
| Queens | 3,333 | 7,981 | 16,894 | 861 | 1,210 |
| The Bronx | 2,783 | 4,535 | 4,612 | 703 | 1,274 |
| Staten Island | 431 | 1,407 | 3,752 | 27 | 52 |
| New York City | 18,440 | 37,934 | 52,888 | 8,933 | 12,333 |
The second table is a sort and not a list of covered buildings. A lot over 25,000 square feet may hold one building or several, and the Department of Buildings decides coverage from its own list. The facade count shows the same gap: DOB says almost 16,000 structures are in the facade program (DOB’s facade statistics), while the tax-lot file shows 12,333 lots of any use whose tallest building has more than six floors. One counts structures and the other counts lots, so they are not expected to match. What the sort does show is how few commercial buildings reach the big laws. In 83% of the city’s commercial lots the building is under 25,000 square feet, and for those lots the weight of the rules falls on boilers, gas, the certificate and the sidewalk. That is where a small-building buyer should start.
Inspections an owner inherits: gas piping, boilers, elevators and cooling towers
Most filings in the matrix are one-time or long-cycle. The ones that come back every year or every few years are gas piping, boilers, elevators and cooling towers, and a buyer should ask the seller to produce the last record of each. Gas piping is on a four-year cycle set by community district (DOB’s gas piping page). The table lists the cycles; community district numbers repeat in each borough, so a district numbered 9 in Queens and one in the Bronx share a sub-cycle.
| Sub-cycle | Community districts | Most recent window | Next window |
|---|---|---|---|
| A | 1, 3, 10 | 2024 | 2028 |
| B | 2, 5, 7, 13, 18 | 2025 | 2029 |
| C | 4, 6, 8, 9, 16 | 2022 | 1 January to 31 December 2026, open now; then 2030 |
| D | 11, 12, 14, 15, 17 | 2023 | 2027 |
Since Local Law 142 of 2025 the inspection covers all exposed gas piping from the building entry to each appliance connection, looks for unsafe conditions, illegal connections and installations that do not meet the code, and includes a leak survey. Boilers are an annual matter: DOB’s boiler page says every boiler in a building is to be inspected annually by a Licensed Master Plumber or a Licensed Oil Burner Installer, and its compliance page narrows that to H- and E-stamped boilers in commercial and mixed-use buildings regardless of capacity. DOB does not grant automatic waivers of boiler violations issued to a prior owner (DOB boiler FAQ), so an unpaid violation can follow the sale. Elevators must be inspected and tested twice a year, and owners must register every cooling tower with the NYC Health Department’s portal.
Before you make an offer, ask for five things in writing: the latest gas piping certification, the latest boiler filing, the elevator test records, the cooling-tower registration if there is a tower, and any facade technical report. A missing record is not proof of a violation, and a clean record is not proof of a sound system. It tells you what to ask next.
Facades and parking structures: two cycles that are changing
The facade program covers buildings with any exterior wall taller than six stories. Only a Qualified Exterior Wall Inspector may do the examination, and unsafe conditions must be repaired within 90 days of filing the technical report. DOB’s page says owners must have the exterior walls and appurtenances inspected every five years. Local Law 49 of 2025, effective 1 October 2026, replaces the fixed cycle with intervals set by DOB rule of between 6 and 12 years (Local Law 49 of 2025). DOB’s own pages still described the five-year cycle on 25 October 2026, the day we read them. Ask the engineer or architect who files for a building which interval applies, and ask again before any offer. Cycle 10 started on 21 February 2025 and runs in three sub-cycles by the last digit of the tax block (DOB’s Cycle 10 table).
| Sub-cycle | Blocks ending in | Filing window |
|---|---|---|
| A | 4, 5, 6, 9 | 21 February 2025 to 21 February 2027 |
| B | 0, 7, 8 | 21 February 2026 to 21 February 2028 |
| C | 1, 2, 3 | 21 February 2027 to 21 February 2029 |
DOB says the share of facade reports filed as unsafe tends to stay in single digits (DOB’s facade statistics). That is a citywide figure and says nothing about the building in front of you.
Parking structures run on their own cycle. A condition assessment must come from a New York State licensed Professional Engineer who is also a DOB Qualified Parking Structure Inspector. DOB’s page puts Bronx, Queens and Staten Island community districts in a window from 1 January 2026 to 31 December 2027 and still says a report is due at least once every six years. Local Law 71 of 2024, effective immediately, says something different: each structure must be assessed at least once by 1 January 2028 and at least every four years after that (Local Law 71 of 2024). Use the local law’s dates, and tell the engineer you have read both.
Outside the front door, the owner carries two more duties. The city says owners must maintain, repair and install the sidewalk next to their property, and tree-root defects beside commercial buildings stay the owner’s (NYC311 sidewalk article). Owners must also keep retaining walls on their property safe. Our Bronx commercial page takes those two up in detail.
The paper trail before you buy or lease
Read the paper before the walk-through, and read the certificate of occupancy first. It states a legal use and the type of occupancy permitted, and the other records only make sense beside it.
| Question | Where to look | What the city says |
|---|---|---|
| What is the legal use? | The certificate of occupancy: the DOB NOW address search for requests on or after 1 March 2021, the Buildings Information System for earlier ones (DOB certificate page) | No one may legally occupy a building until DOB has issued a certificate or a temporary one. An existing building needs a current or amended certificate when use, egress or type of occupancy changes, which is why a tenant’s change of use can trigger a new one |
| The building has no certificate | The DOB borough office, for a Letter of No Objection | A building from before 1938 is not required to have one unless later alterations changed use, egress or occupancy; legal use is then shown by the letter |
| Can the seller cure a mismatch? | The same page | DOB will not issue a certificate while applications or violations on the property are open |
| Are violations open? | The Buildings Information System; OATH hearings (DOB on OATH summonses) | A violation stays open on the property’s profile until it is dismissed at a hearing or resolved by a Certificate of Correction, and paying an OATH penalty does not close a DOB violation (DOB compliance FAQ) |
| Could the use be shut down? | DOB’s Padlock Unit (DOB page on illegal home use) | It stops illegal manufacturing and commercial uses in residential neighborhoods and certain commercial districts |
| What is recorded against the title? | ACRIS (Department of Finance) | It searches recorded deeds and mortgages for Manhattan, Queens, the Bronx and Brooklyn from 1966; the description does not list Staten Island |
| Are there apartments over the store? | HPD registration (HPD) | A multiple dwelling of three or more residential units must register each year, with a deadline of 1 September |
| What are the building’s permits, complaints and history? | The Buildings Information System and the DOB NOW public portal (DOB building data page) | Anyone can review a building’s violations, permits and complaints there |
If the walk-through finds a second use, an unlabeled mezzanine, or a kitchen where the certificate shows an office, the mismatch goes to your attorney and to the seller before it goes anywhere else. We report what is visible and we do not decide legal use. Our page on pre-purchase commercial inspection and our commercial inspection checklist cover the buyer’s side of the visit.
What lenders ask of the person who writes the condition report
Lenders do not all ask for the same thing, and Freddie Mac says plainly that it approves nobody. The first two programs below are multifamily guides; for a store, office or warehouse financed by a bank, the bank’s own policy applies, so ask for its consultant requirements in writing before you hire anyone.
| Program | What it asks of the consultant and the report | Source |
|---|---|---|
| Fannie Mae Multifamily Guide | A property condition assessment for each property before the commitment date, except a streamlined supplemental loan. Form 4099 asks the consultant, individually or collectively, for a bachelor’s degree in engineering, architecture, construction management or a related field. It lists InterNACHI among acceptable field-observer credentials, next to others, and asks the field observer for three years of assessment experience and five multifamily inspections. The finished report is reviewed and certified by a Professional Engineer, a registered architect or an individual with appropriate construction-field experience and certifications, who must be an employee of the consultant | Fannie Mae Guide · Form 4099 |
| Freddie Mac Multifamily Guide, Chapter 62 | A property condition report. The lender reviews the consultant’s licensing and certifications where they apply; it must disregard any claim that a consultant is approved or qualified by Freddie Mac; the report identifies deviations from the Guide and from the most recent version of ASTM E2018; and the consultant checks public sources for open zoning, building, accessibility, fire and energy violations | Freddie Mac |
| HUD-insured refinancing (223(f) and 223(a)(7)) | The lender retains a qualified Needs Assessor who completes a Capital Needs Assessment | a public copy of HUD Handbook 4430.G |
Three consequences follow. A credential on a list is not an approval. We make no claim of lender approval: Freddie Mac approves no consultants, and Fannie Mae makes the lender justify a consultant who lacks the Form 4099 credentials. Under Fannie Mae’s form the field observer and the certifying reviewer are different roles. And a report that suits one program may not suit another, so give the lender’s requirements to whoever you hire at the start, not at the end.
Lender reports also use their own vocabulary for what has to be fixed and when. The words overlap, and the clocks differ, so read the definition and not the label.
| Term | Fannie Mae | Freddie Mac | ASTM E2018 (2015 text) |
|---|---|---|---|
| Most urgent items | “Critical repairs” should typically be addressed immediately or within six months of the report date | “Critical repairs” address conditions that significantly impair habitability, safety, value, income or marketability, and must be corrected before Freddie Mac proceeds | “Immediate costs” cover material unsafe conditions, material building or fire code violations, or deficiencies likely to cause a critical failure within a year |
| Aging systems and other fixes | “Deferred maintenance” means non-recurring capital items approaching, at or past their estimated useful life, typically fixed within 12 months | “Priority repairs” include life-safety hazards, violations of zoning, building, accessibility, health, fire or energy rules, and deferred maintenance, due within 365 days after origination | — |
Where to read next
For a commercial building inspection NYC borough by borough, each page uses different records. Manhattan and Staten Island have their own commercial pages; Brooklyn’s covers converted industrial and landmark buildings, Queens’s the storefront building with apartments above, and the Bronx’s emissions limits, tanks and sidewalks. For the houses that sit beside these buildings, see home inspection in New York City, Manhattan and the other borough pages. Our existing service pages describe the work in more detail: commercial real estate property inspection services, commercial roof inspections and property condition assessment. The guide to what a New York home inspection includes explains the residential side that our state license covers.
Frequently asked questions
Does a commercial building inspection satisfy the facade, gas piping or Local Law 97 requirements?
No. Each of those has its own signer: a Qualified Exterior Wall Inspector for the facade, a Licensed Master Plumber for gas piping and a registered design professional for the Local Law 97 report. A walk-through does not replace any of them.
Is Inspecwise licensed to inspect commercial buildings?
Our license is a New York State home inspector license, which covers residential buildings of one to four dwelling units. We offer a visual, non-invasive walk-through of commercial buildings and claim no other license. That work is not engineering or architecture.
Which New York City buildings need a facade inspection?
Buildings with any exterior wall greater than six stories, whatever the certificate of occupancy says. Local Law 49 of 2025 lets DOB set the interval at 6 to 12 years from 1 October 2026, and DOB’s pages still showed five years when we read them.
Do I need a Phase I report if I already have a condition report?
A condition report does not answer the environmental question. A lender such as the SBA may require a Phase I, or a Phase I and a Phase II for a dry cleaner, and it must come from an environmental professional.
Who can sign a property condition assessment for a lender?
It depends on the lender. Fannie Mae asks for review and certification by a Professional Engineer, a registered architect or someone with construction-field experience and certifications. Freddie Mac says it approves no consultants. Get the lender’s rule in writing.
How do I check a building’s legal use before an offer?
Read its certificate of occupancy in DOB NOW or the Buildings Information System. A building from before 1938 may have none, and DOB can then issue a Letter of No Objection to confirm legal use.
When is a building’s next gas piping inspection due?
It depends on the community district: 2026 for districts 4, 6, 8, 9 and 16, 2027 for 11, 12, 14, 15 and 17, 2028 for 1, 3 and 10, and 2029 for 2, 5, 7, 13 and 18. One- and two-family homes and other R-3 buildings are excluded.
What is the difference between a property condition assessment and what Inspecwise offers?
A property condition assessment follows ASTM E2018: a walk-through, research, a reviewer and a qualifications statement. Inspecwise describes its commercial work as aligned with that baseline process, so ask which of those parts your report contains.
About the figures on this page
- NYC Department of City Planning, PLUTO, version 26v2. A commercial lot is a tax lot with commercial floor area recorded; floor areas are Department of Finance square feet. Size bands use the lot’s total building area. “More than six floors” uses the floor count of the tallest building on the lot. Counts are lots, not buildings or businesses. The year built for old buildings is often a rounded estimate, so only the share built before 1940 is quoted.
- NYC Department of Finance building classes: the class families (S mixed residential-commercial, K retail, O office, E warehouse, F factory, G garage, C walk-up apartments, D elevator apartments) are the first letter of each lot’s building class.
- Rules and deadlines come from the Department of Buildings, HPD, DEP, the NYC Health Department, the state’s Real Property Law and Education Law, ASTM International’s published descriptions, EPA, the SBA and the Fannie Mae and Freddie Mac guides, linked where each is used. The facade and parking-structure rules are changing, and we read the pages on 25 October 2026; check the current text before you rely on a date.
Before you hire anyone for a commercial building
To prepare for a commercial building inspection NYC buyers and owners can book, collect the certificate of occupancy, the last gas piping and boiler filings, any facade technical report and your lender’s written requirements, and send them to us with the building’s address, number of stories, approximate square feet and whether any apartments sit above the store. With those, we can tell you which parts of this page apply and what a walk-through can and cannot settle.
If a visit is what you need, tell us which language you would like for the walk-through. The footer of every page carries our state license number. We work in the five boroughs, Nassau, Suffolk and Westchester, and elsewhere on request.
Prefer to talk first? Call 718-925-7071.